MCX technium
The new generation of One To One unit
Specifically designed for industrial operators seeking to control their building energy performance, control and separate air flows supplied in their different spaces. For constrained environments or work areas in corrosive or dust-laden atmospheres, the MCX Technium range is appropriate.
AIRFLOW
800 – 50,000 m³/h
Airflow 800 – 50,000 m³/h
—
70 mm double-skin walls
—
Recovery wheel, counterflow plate exchanger or recovery coils
—
Slide-mounting filters, front or side removal
—
Indoor or outdoor placement
—
Certified by Eurovent
—
/ APPLICATIONS
Schools · Sports centers · Non-residential buildings · Refurbishment projects
/ THE MCX PLATFORM
Modular Compact Air Handling Unit
A flexible modular design with a wide range of components to fit every need: 21 single flow sections and 24 double flow sections, with up to 110,000 component and housing combinations.
Casing & design
Dual-wall insulation, 50 or 70 mm
—
Continuous insulation without thermal bridge — class T2 & TB2
—
Air tightness class L1, mechanical strength class D1
—
Patented X-DOOR full-height access door
—
Filters
—
ePM10 to ePM1, and HEPA from E10 to H14
—
Bag, flat, pleated or active carbon, single or combined
—
Adjustable filter railway, F9 compatible
Fans & controls
EC plug fan motor, IE5
—
—
Anti-vibration air connection frame
—
Integrated electrical cabinet and cable tray
—
Pre-wired power cable
Coils & heat recovery
—
Coils manufactured in-house — hot water, steam, cold water, evaporator
—
Copper or stainless-steel tubes, special Heresite coatings
—
Recovery wheel, counterflow plate exchanger or recovery coils
X-DOOR
A patented full-height door that ensures an airtight seal for thermal insulation between the tunnel and the door. The door is mounted on special hinges that allow it to be easily and completely removed.
FILTER FLOW RATE (M³/H)
Single flow
Double flow
with recovery wheel
Double flow
with plate exchanger
0
10k
20k
30k
40k
50k
Components are selected for each project from the first consultation — including BIM schematics. See how selection works →
Built section by section
/ TECHNOLOGY
Each MCX is assembled from sections selected for the project, not adapted from a standard unit. Solid 70 mm double-skin walls, controlled air leakage and reduced system effects — specified once, delivered as specified.
800 – 50,000 m³/h
AIRFLOW RANGE
70 mm
DOUBLE-SKIN WALLS
3 types
HEAT RECOVERY

Contact
Write us
For any questions, call us on: +33 (0) 2 33 85 14 00
Or fill in the form to the right and we will get back to you shortly.
ADDRESS
Route de Paris, ZI la Grippe
61400 Mortagne-au-Perche
Expertise that transforms air
© 2026 Hydronic. All rights reserved.